Abstract:Diffusion Posterior Sampling(DPS) methodology is a novel framework that permits nonlinear CT reconstruction by integrating a diffusion prior and an analytic physical system model, allowing for one-time training for different applications. However, baseline DPS can struggle with large variability, hallucinations, and slow reconstruction. This work introduces a number of strategies designed to enhance the stability and efficiency of DPS CT reconstruction. Specifically, jumpstart sampling allows one to skip many reverse time steps, significantly reducing the reconstruction time as well as the sampling variability. Additionally, the likelihood update is modified to simplify the Jacobian computation and improve data consistency more efficiently. Finally, a hyperparameter sweep is conducted to investigate the effects of parameter tuning and to optimize the overall reconstruction performance. Simulation studies demonstrated that the proposed DPS technique achieves up to 46.72% PSNR and 51.50% SSIM enhancement in a low-mAs setting, and an over 31.43% variability reduction in a sparse-view setting. Moreover, reconstruction time is sped up from >23.5 s/slice to <1.5 s/slice. In a physical data study, the proposed DPS exhibits robustness on an anthropomorphic phantom reconstruction which does not strictly follow the prior distribution. Quantitative analysis demonstrates that the proposed DPS can accommodate various dose levels and number of views. With 10% dose, only a 5.60% and 4.84% reduction of PSNR and SSIM was observed for the proposed approach. Both simulation and phantom studies demonstrate that the proposed method can significantly improve reconstruction accuracy and reduce computational costs, greatly enhancing the practicality of DPS CT reconstruction.
Abstract:Spectral CT offers enhanced material discrimination over single-energy systems and enables quantitative estimation of basis material density images. Water/iodine decomposition in contrast-enhanced CT is one of the most widespread applications of this technology in the clinic. However, low concentrations of iodine can be difficult to estimate accurately, limiting potential clinical applications and/or raising injected contrast agent requirements. We seek high-sensitivity spectral CT system designs which minimize noise in water/iodine density estimates. In this work, we present a model-driven framework for spectral CT system design optimization to maximize material separability. We apply this tool to optimize the sensitivity spectra on a spectral CT test bench using a hybrid design which combines source kVp control and k-edge filtration. Following design optimization, we scanned a water/iodine phantom with the hybrid spectral CT system and performed dose-normalized comparisons to two single-technique designs which use only kVp control or only kedge filtration. The material decomposition results show that the hybrid system reduces both standard deviation and crossmaterial noise correlations compared to the designs where the constituent technologies are used individually.