Abstract:Radiology AI models have made significant progress in near-human performance or surpassing it. However, AI model's partnership with human radiologist remains an unexplored challenge due to the lack of health information standards, contextual and workflow differences, and data labeling variations. To overcome these challenges, we integrated an AI model service that uses DICOM standard SR annotations into the OHIF viewer in the open-source LibreHealth Radiology Information Systems (RIS). In this paper, we describe the novel Human-AI partnership capabilities of the platform, including few-shot learning and swarm learning approaches to retrain the AI models continuously. Building on the concept of machine teaching, we developed an active learning strategy within the RIS, so that the human radiologist can enable/disable AI annotations as well as "fix"/relabel the AI annotations. These annotations are then used to retrain the models. This helps establish a partnership between the radiologist user and a user-specific AI model. The weights of these user-specific models are then finally shared between multiple models in a swarm learning approach.
Abstract:Barten's model of spatio-temporal contrast sensitivity function of human visual system is embedded in a multi-slice channelized Hotelling observer. This is done by 3D filtering of the stack of images with the spatio-temporal contrast sensitivity function and feeding the result (i.e., the perceived image stack) to the multi-slice channelized Hotelling observer. The proposed procedure of considering spatio-temporal contrast sensitivity function is generic in the sense that it can be used with observers other than multi-slice channelized Hotelling observer. Detection performance of the new observer in digital breast tomosynthesis is measured in a variety of browsing speeds, at two spatial sampling rates, using computer simulations. Our results show a peak in detection performance in mid browsing speeds. We compare our results to those of a human observer study reported earlier (I. Diaz et al. SPIE MI 2011). The effects of display luminance, contrast and spatial sampling rate, with and without considering foveal vision, are also studied. Reported simulations are conducted with real digital breast tomosynthesis image stacks, as well as stacks from an anthropomorphic software breast phantom (P. Bakic et al. Med Phys. 2011). Lesion cases are simulated by inserting single micro-calcifications or masses. Limitations of our methods and ways to improve them are discussed.