Abstract:Pre-processing and Data Augmentation play an important role in Deep Convolutional Neural Networks (DCNN). Whereby several methods aim for standardization and augmentation of the dataset, we here propose a novel method aimed to feed DCNN with spherical space transformed input data that could better facilitate feature learning compared to standard Cartesian space images and volumes. In this work, the spherical coordinates transformation has been applied as a preprocessing method that, used in conjunction with normal MRI volumes, improves the accuracy of brain tumor segmentation and patient overall survival (OS) prediction on Brain Tumor Segmentation (BraTS) Challenge 2020 dataset. The LesionEncoder framework has been then applied to automatically extract features from DCNN models, achieving 0.586 accuracy of OS prediction on the validation data set, which is one of the best results according to BraTS 2020 leaderboard.
Abstract:Magnetic Resonance Imaging (MRI) is used in everyday clinical practice to assess brain tumors. Several automatic or semi-automatic segmentation algorithms have been introduced to segment brain tumors and achieve an expert-like accuracy. Deep Convolutional Neural Networks (DCNN) have recently shown very promising results, however, DCNN models are still far from achieving clinically meaningful results mainly because of the lack of generalization of the models. DCNN models need large annotated datasets to achieve good performance. Models are often optimized on the domain dataset on which they have been trained, and then fail the task when the same model is applied to different datasets from different institutions. One of the reasons is due to the lack of data standardization to adjust for different models and MR machines. In this work, a 3D Spherical coordinates transform during the pre-processing phase has been hypothesized to improve DCNN models' accuracy and to allow more generalizable results even when the model is trained on small and heterogeneous datasets and translated into different domains. Indeed, the spherical coordinate system avoids several standardization issues since it works independently of resolution and imaging settings. Both Cartesian and spherical volumes were evaluated in two DCNN models with the same network structure using the BraTS 2019 dataset. The model trained on spherical transform pre-processed inputs resulted in superior performance over the Cartesian-input trained model on predicting gliomas' segmentation on tumor core and enhancing tumor classes (increase of 0.011 and 0.014 respectively on the validation dataset), achieving a further improvement in accuracy by merging the two models together. Furthermore, the spherical transform is not resolution-dependent and achieve same results on different input resolution.