Abstract:Human-machine teaming in medical AI requires us to understand to what degree a trained clinician should weigh AI predictions. While previous work has shown the potential of AI assistance at improving clinical predictions, existing clinical decision support systems either provide no explainability of their predictions or use techniques like saliency and Shapley values, which do not allow for physician-based verification. To address this gap, this study compares previously used explainable AI techniques with a newly proposed technique termed '2-factor retrieval (2FR)', which is a combination of interface design and search retrieval that returns similarly labeled data without processing this data. This results in a 2-factor security blanket where: (a) correct images need to be retrieved by the AI; and (b) humans should associate the retrieved images with the current pathology under test. We find that when tested on chest X-ray diagnoses, 2FR leads to increases in clinician accuracy, with particular improvements when clinicians are radiologists and have low confidence in their decision. Our results highlight the importance of understanding how different modes of human-AI decision making may impact clinician accuracy in clinical decision support systems.
Abstract:Thermal cameras and thermal point detectors are used to measure the temperature of human skin. These are important devices that are used everyday in clinical and mass screening settings, particularly in an epidemic. Unfortunately, despite the wide use of thermal sensors, the temperature estimates from thermal sensors do not work well in uncontrolled scene conditions. Previous work has studied the effect of wind and other environment factors on skin temperature, but has not considered the heating effect from sunlight, which is termed solar loading. Existing device manufacturers recommend that a subject who has been outdoors in sun re-acclimate to an indoor environment after a waiting period. The waiting period, up to 30 minutes, is insufficient for a rapid screening tool. Moreover, the error bias from solar loading is greater for darker skin tones since melanin absorbs solar radiation. This paper explores two approaches to address this problem. The first approach uses transient behavior of cooling to more quickly extrapolate the steady state temperature. A second approach explores the spatial modulation of solar loading, to propose single-shot correction with a wide-field thermal camera. A real world dataset comprising of thermal point, thermal image, subjective, and objective measurements of melanin is collected with statistical significance for the effect size observed. The single-shot correction scheme is shown to eliminate solar loading bias in the time of a typical frame exposure (33ms).