Abstract:Reliability assessment of distribution system, based on historical data and probabilistic methods, leads to an unreliable estimation of reliability indices since the data for the distribution components are usually inaccurate or unavailable. Fuzzy logic is an efficient method to deal with the uncertainty in reliability inputs. In this paper, the ENS index along with other commonly used indices in reliability assessment are evaluated for the distribution system using fuzzy logic. Accordingly, the influential variables on the failure rate and outage duration time of the distribution components, which are natural or human-made, are explained using proposed fuzzy membership functions. The reliability indices are calculated and compared for different cases of the system operations by simulation on the IEEE RBTS Bus 2. The results of simulation show how utilities can significantly improve the reliability of their distribution system by considering the risk of the influential variables.